Tens of thousands of competitors, pages of hard questions and unsatisfied exam preparation situations… Do not worried about all those annoying things! We, help you with your Netapp Other Certification NS0-173 Cisco and NetApp FlexPod Design Specialist exam. We will assist you clear the NS0-173 exam with Netapp Other Certification NS0-173 exam questions. We NS0-173 actual tests are the most comprehensive ones.
Visit our site to get more NS0-173 Q and As:https://www.dumps4sure.com/ns0-173.html (60 QAs Dumps)
Question 1:
Your customer has a FlexPod configuration with a 4-node NetApp AFF A300 storage cluster that uses only NSE drives.
Which two solutions allow the customer to expand the current storage system? (Choose two.)
A. a two-node AFF A200 with a 3.8 TB NSE SSD
B. a DS224C with twenty-four 3.8 TB SSDs
C. a DS4246 with twenty-four 6 TB NL-SAS HDDs
D. a two-node FAS8200 with a 4 TB NL-SAS HDD
Correct Answer: BD
Question 2:
A customer wants to deploy a FlexPod solution that involves directly connecting the NetApp AFF storage using the FCoE protocol to the Cisco UCS Fabric Interconnects.
In this scenario, which Cisco UCS Fibre Channel mode would be used to accomplish this task?
A. trunk mode
B. end host mode
C. switching mode
D. access mode
Correct Answer: C
Reference: https://www.netapp.com/media/16411-nva-0025-deploy.pdf
Question 3:
The storage administrator must change the vHBA settings bound to a template associated with a production server.
What happens when the settings are reconfigured in this scenario?
A. The vHBA configuration change does not affect LUN access.
B. The server that is associated with the service profile reboots.
C. The service profile template that is associated with the server is initialized.
D. The vHBA template is deleted from UCS Manager.
Correct Answer: C
Question 4:
You are a data center architect at a service provider. You need to configure a new multi-tenant FlexPod service offering.
Which three UCS Manager features will you need to accomplish this task? (Choose three.)
A. auto discovery
B. role-based access control
C. service profiles
D. virtualization support
E. policies
Correct Answer: BCE
Question 5:
A customer is evaluating management tools for a new FlexPod infrastructure. They desire a tool that can orchestrate the provisioning of UCS compute nodes, NetApp storage, and VMware networking.
Which tool satisfies the requirements of this customer\’s heterogeneous environment?
A. UCS Central
B. NetApp OnCommand Unified Manager
C. NetApp OnCommand Insight
D. UCS Director
Correct Answer: D
Question 6:
An administrator decides to connect storage directly to UCS Fabric Interconnect to support FCoE within a FlexPod configuration.
In this scenario, which port type should be defined on the Fabric Interconnect ports that are connected to the storage controller?
A. monitor port
B. appliance port
C. uplink port
D. server port
Correct Answer: C
Question 7:
A customer has deployed a FlexPod Datacenter with Red Hat Enterprise Linux OpenStack Platform. The Cinder storage volumes that are attached to the Nova instances are not available.
Based on the terms of the cooperative support model, which three companies would the customer use to open a support case? (Choose three.)
A. Cisco
B. VMware
C. Microsoft
D. NetApp
E. Red Hat
Correct Answer: ADE
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/ flexpod_openstack_osp6_design.html
Question 8:
Click the Exhibit button.
A customer wants to ensure that FlexPod Datacenter connections to the storage layer are highly available. Which two configurations shown in the exhibit satisfy the customer\’s requirements? (Choose two.)
A. I.
B. II.
C. III.
D. IV
Correct Answer: CD
Question 9:
A customer has a FlexPod Express configuration with a FAS2720 system. The company has opened a new remote location and will purchase a FlexPod Express configuration with a FAS2750 system. The business requires that the data be replicated to the new location.
Which two software applications accomplish this task? (Choose two.)
A. SnapVault
B. SnapRestore
C. SnapMirror
D. FlexCache
Correct Answer: CD
FlexClone: Instant virtual copies with file and volume granularity SnapMirror: Integrated data replication technology for simple, efficient, flexible disaster recovery and backup use cases
Reference: https://www.inneo.ch/files/content/Informationstechnologien/Storage-Server-Netzwerk/ datenblatt-netapp-fas-2700-storage.pdf
Question 10:
A customer wants to design a FlexPod configuration based on a CVD that was published 10 months ago. The customer wants to ensure that they are using the latest hardware and software versions.
In this scenario, which two tools are used to identify the latest supported hardware and software? (Choose two.)
A. NetApp Interoperability Matrix Tool
B. NetApp OnCommand System Manager
C. Cisco UCS Hardware and Software Interoperability Matrix
D. Cisco UCS Director
Correct Answer: CD
C: When using this matrix to determine recommended driver versions for you server configuration, please reference the server\’s Blade/Rack Bundle firmware version for the recommended driver in the event that your servers are running Mixed Firmware from your Infrastructure Bundle.
D: Cisco UCS Director delivers unified, highly secure management for supported compute, network, storage, and virtualization platforms and for the industry\’s leading converged infrastructure solutions
Reference: https://ucshcltool.cloudapps.cisco.com/public/# https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-director/release-notes/6-7/cisco-ucsdirector-release-notes-67.html
Question 11:
You are designing a FlexPod solution that requires 32 ports running at 40 Gbps.
To satisfy this requirement, which Cisco Fabric Interconnect should you deploy?
A. 6332-16UP
B. 6332
C. 6248UP
D. 6296UP
Correct Answer: B
FI 6332 is a one-rack-unit (1RU) 40 Gigabit Ethernet, and FCoE switch offering up to 2.56 Tbps throughput
and up to 32 ports. The switch has 32 40Gbps fixed Ethernet.
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/
flexpod_esxi60u2_fc_design.html
Question 12:
You are configuring high availability within the network layer of your FlexPod configuration.
In this scenario, what are two Cisco best practices for designing vPC on your Cisco 9000 Series switches? (Choose two.)
A. Peer keep-alive connectivity between the switches should be established.
B. A minimum of four 10GB Ethernet connections are required for vPC.
C. The vPC auto-recovery feature should be enabled.
D. Port channels should be configured for LACP passive mode.
Correct Answer: AB
vPC also relies on the periodic keepalive messages to determine when one of the connected devices on the peer link fails. vPC peer link ?The link used to synchronize states between the vPC peer devices. Both ends must be on 10-Gigabit Ethernet or 40-Gigabit Ethernet interfaces. Reference: https://www.cisco.com/ c/en/us/td/docs/switches/datacenter/nexus9000/sw/6-x/interfaces/configuration/guide/ b_Cisco_Nexus_9000_Series_NX-OS_Interfaces_Configuration_Guide/ b_Cisco_Nexus_9000_Series_NX- OS_Interfaces_Configuration_Guide_chapter_0111.html
Question 13:
A customer is using a FlexPod implementation that has 10 Gbps uplinks from the B-Series chassis to the fabric interconnect. The customer wants to upgrade the links to 40 Gbps.
In this scenario, which model of Cisco UCS server IOM is required?
A. 2204XP.
B. 2208XP
C. 2232
D. 2304
Correct Answer: A
The Cisco UCS 2204XP Fabric Extender (Figure 7) has four 10 Gigabit Ethernet, FCoE-capable, SFP ports that connect the blade chassis to the fabric interconnect. Reference: https://www.cisco.com/c/dam/ en/us/products/collateral/servers-unified-computing/ucs-b-series-blade-servers/spec_sheet_c17644224.pdf
Question 14:
Your customer wants assurances that all aspects of FlexPod are highly available.
Which statement is correct in this scenario?
A. Cisco UCS Manager contains multiple UCS domains.
B. Cisco UCS Manager automatically copies its configuration data to a remote data store.
C. Cisco UCS Manager uses active-active architecture.
D. Cisco UCS Manager maintains a replica of configuration information.
Correct Answer: D
The management and data plane of Cisco UCS is designed for high availability and redundant access layer fabric interconnects. In addition, Cisco UCS supports existing high availability and disaster recovery solutions for the data center, such as data replication and application-level clustering technologies. Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/ Infrastructure-Mgmt/3-1/b_UCSM_GUI_Infrastructure_Management_Guide_3_1/ b_UCSM_GUI_Infrastructure_Management_Guide_3_1_chapter_0110.html
Question 15:
A customer has several existing standalone Cisco UCS C-Series servers that they would like to repurpose and add to their FlexPod Datacenter solution.
Which action should the customer perform on these servers before using UCS Manager?
A. Zero-out the FlexFlash cards on each server.
B. Reboot the CIMC on each server.
C. Remove the hard disks on each server.
D. Reset the CIMC to the factory settings on each server.
Correct Answer: D
On rare occasions, such as an issue with the current running firmware, troubleshooting a server may require you to reset the CIMC to the factory default. When this happens, all user-configurable settings are reset. This procedure is not part of the normal server maintenance. After you reset the CIMC, you are logged off and must log in again. You may also lose connectivity and may need to reconfigure the network settings. Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/sw/cli/config/guide/1-0_1x/ b_Cisco_CIMC_C250_CLI_Configuration_Guide/ Cisco_CIMC_C250_CLI_Configuration_Guide_chapter13.pdf
Visit our site to get more NS0-173 Q and As:https://www.dumps4sure.com/ns0-173.html (60 QAs Dumps)