[PDF and VCE] Free 5V0-21.21 VCE and PDF, Exam Materials Instant Download

Tens of thousands of competitors, pages of hard questions and unsatisfied exam preparation situations… Do not worried about all those annoying things! We, help you with your VMware Certified Master Specialist – HCI 2021 May 31,2022 Newest 5V0-21.21 exam questions VMware HCI Master Specialist Dumps exam. We will assist you clear the Newest 5V0-21.21 pdf dumps exam with VMware Certified Master Specialist – HCI 2021 5V0-21.21 real exam questions. We latest 5V0-21.21 dumps are the most comprehensive ones.

We Geekcert has our own expert team. They selected and published the latest 5V0-21.21 preparation materials from Official Exam-Center.

The following are the 5V0-21.21 free dumps. Go through and check the validity and accuracy of our 5V0-21.21 dumps.Free sample questions of 5V0-21.21 free dumps are provided here. All the following questions are from the latest real 5V0-21.21 dumps.

Question 1:

In a stretched vSAN cluster, how is Read Locality established after fail over to the secondary site?

A. 100% of the reads comes from vSAN hosts on the local site

B. 50% of the reads comes from vSAN hosts on the local site

C. 100% of the reads comes from vSAN hosts on the remote site

D. 50% of the reads comes from vSAN hosts on the remote site

Correct Answer: A

Reference: https://www.vmware.com/files/pdf/products/vsan/vmware-virtual-san-6.1-stretched-clusterguide.pdf (45)


Question 2:

An architect needs to automate an infrastructure that supports VMware Horizon as well as VMware Tanzu. Which solution mandates the use of VMware vSAN?

A. VMware Cloud Foundation

B. VMware Horizon

C. VMware Tanzu

D. VMware vRealize Automation

Correct Answer: D

Reference: https://www.vmware.com/products/vrealize-automation.html


Question 3:

An administrator is setting up vSAN file services on a vSAN cluster.

Which two security policies on the distributed port groups are automatically enabled in the process? (Choose two.)

A. Forged Transmits

B. Promiscuous Mode

C. DVFiltering

D. Jumbo Frames

E. MacLearning

Correct Answer: AB

Reference: https://www.yellow-bricks.com/2020/04/15/vsan-file-services-considerations/


Question 4:

An administrator has been tasked to reboot a node in an encrypted vSAN cluster. The vSAN disk groups on that node become locked after rebooting the node.

Which step should be performed to exit the locked state?

A. Manually replace the Host Encryption Key (HEK) of each affected host.

B. Restore the communication with the KMS server, and re-establish the trust relationship.

C. Replace the caching device in each affected disk group.

D. Run /etc/init.d/vsanvpd restart to rescan the VASA providers.

Correct Answer: B


Question 5:

A company hosts a vSAN 7 stretched cluster for all development workloads. The original sizing of a maximum of 250 concurrent workloads in the vSAN cluster is no longer sufficient and needs to increase to at least 500 concurrent workloads within the next six months.

To meet this demand, the original 8-node (4-4-1) cluster has recently been expanded to 16 nodes (8-8-1).

Which three additional steps should the administrator take to support the current growth plans while minimizing the amount of resources required at the witness site? (Choose three.)

A. Add the new vSAN witness appliance to vCenter Server.

B. Deploy a new large vSAN witness appliance at the witness site.

C. Configure the vSAN stretched cluster to use the new vSAN witness.

D. Deploy a new extra large vSAN witness appliance at the witness site.

E. Upgrade the vSAN stretched cluster to vSAN 7.0 U1.

F. Configure the new vSAN witness as a shared witness appliance.

Correct Answer: BCF


Question 6:

Upon investigating a workload performance issue, a vSAN administrator observed a high backend IOPs on a vSAN cluster.

Which two causes explain this behavior? (Choose two.)

A. The cluster DRS threshold has been set to Aggressive.

B. There is a vSAN node failure.

C. The vSAN Resync throttling is enabled.

D. The object repair timer value has been increased.

E. The vSAN policy protection level has changed from FTT=0 to FTT=1.

Correct Answer: CE

Reference: https://core.vmware.com/resource/troubleshooting-vsan-performance#_Toc536646878


Question 7:

An administrator wants to check the performance metrics for the workloads and their virtual disks that are running on a vSAN cluster, but no statistical charts are displayed in the vSphere client.

Why is this behavior being seen?

A. vSAN network diagnostic mode is not enabled.

B. vSAN proactive tests haven\’t been run yet.

C. vSAN performance service is turned off.

D. vSAN performance verbose mode is not enabled.

Correct Answer: C

Some tools allow for measuring latency peaks. This unfortunately isn\’t ideal, as it can unfairly represent statistical outliers, which may very well occur when there is little to no I/O activity. The best way to understand the actual behavior of VM and application latencies is to observe in time based performance graphs. Depending on the level of detail, you may need to measure at the individual VMDK level. Become familiar with these graphs to determine what is normal, and what is not for that given application. This is where you can use built-in functionality of vCenter and the vSAN performance service metrics to gather this information.

Reference: https://core.vmware.com/resource/troubleshooting-vsan-performance#_Toc536646873


Question 8:

During a maintenance action on a vSAN node, a vSAN administrator noticed that the default repair delay time is about to be reached.

Which two commands must be run to extend the time? (Choose two.)

A. /etc/init.d/vsanmgmtd restart

B. esxcli system settings advanced set -o /VSAN/ClomRepairDelay -i 50

C. esxcli system settings advanced set -o /VSAN/ClomRepairDelay -i 80

D. /etc/init.d/clomd restart

E. /etc/init.d/vsanobserver restart

Correct Answer: CD

Reference: https://kb.vmware.com/s/article/2075456


Question 9:

An administrator wants to deploy a desktop and application virtualization solution on top of vSAN. Which VMware product should the administrator install?

A. VMware Dynamic Environment Manager

B. VMware Horizon Apps

C. VMware Workspace One Access

D. VMware Horizon

Correct Answer: D


Question 10:

An administrator has been tasked with enabling encryption for existing virtual machines on a vSAN cluster. Which three prerequisites must be satisfied before completing the task? (Choose three.)

A. Create an encryption storage policy

B. Enable Data-In-Transit encryption first

C. Enable that the virtual machines are powered on

D. Verify if a role with privilege “Cryptographic operations.Encrypt new” is assigned

E. Verify if a role with privilege “Cryptographic operations.Migrate” is assigned

F. Establish a trusted connection with the KMS

Correct Answer: CDF


Question 11:

Upon checking the latency goal under vSAN performance diagnostics, the vSAN Administrator sees this

message displayed:

The increase in latency in the vSAN stack might be beyond expected limits.

Which two root causes can be identified to help remediate the issue? (Choose two.)

A. vSAN VMKemel portgroup is configured with the “Route based on IP hash” teaming policy

B. vSAN encryption is enabled

C. Large packet losses and retransmissions on the network layer

D. Incorrect sizing of the disk groups capacity disks

E. One or more disk groups are congested

Correct Answer: CE

Reference: https://kb.vmware.com/s/article/2150018


Question 12:

An administrator has received an alert indicating that a single capacity device is close to failing within the production vSAN Cluster. The administrator must now complete preemptive maintenance on the vSAN Cluster without impacting the availability of workloads or vSAN File Services.

The following information is known about the vSAN Cluster: vSAN 7.x Cluster vSAN node count: 8 De-Duplication and Compression: Enabled. Encryption: Disabled Current Utilization: 45% Disk Groups: 2 Devices per node: 2 x 400 GB SSD, 6 x 1.8 TB SSD

Which three steps should the administrator take to successfully complete the task? (Choose three.)

A. Remove the affected Disk Group from the vSAN Cluster, and choose Full Data Migration.

B. Replace the failed disk with a storage device that is identical in class and capacity.

C. Remove the affected Disk Group from the vSAN Cluster, and choose No Data Migration.

D. Replace the failed disk with a storage device that is identical in class but smaller in capacity.

E. Put the affected vSAN host into maintenance mode to physically replace the storage device.

F. Remove the affected Disk from the Disk Group, and choose Full Data Migration.

Correct Answer: ABF


Question 13:

A 30-minute power maintenance window has been approved on Sunday. Due to a delay, the maintenance took 20 minutes longer to finish.

During this time, the vSAN administrator noticed that one of the clusters nodes was affected by a power shortage, as it was connected to an affected power source. The default vSAN storage policy has been applied.

What will be the status of the vSAN objects on the affected host immediately after it is recovered?

A. The cluster will be partitioned and the vSAN host will need to be rejoined.

B. A rebuild of the affected objects will occur.

C. All objects will remain accessible.

D. All objects on the affected host will be lost.

Correct Answer: B


Question 14:

Due to the success of the recently deployed developer-only private cloud solution, a company has a new requirement to at least double the usable capacity in their all-flash vSAN cluster.

The vSAN cluster is deployed into a co-located datacenter that is owned by a third-party hosting company. The hosting company charges a fixed monthly cost for rack space and power consumption. The service owner has been given a limited budget for additional hardware purchases, but not for on-going co-location costs.

The current vSAN cluster has the following configuration: 10 vSAN Nodes with 2 CPUs (20 cores), 512 GB RAM

1 Disk Group per vSAN node

-1 x 400 GB

-4 x 1.8 TB

De-duplication and Compression is enabled.

vSAN Capacity is currently:

-Total: 72 TB

-Usable: ~40 TB (FTT1/RAID1) and ~60 TB (FTT1/RAID5).

As a result of any action taken, the service owner would like to ensure that overall availability of the vSAN cluster is increased.

Which two recommendations meet the requirement to increase capacity while maintaining service availability? (Choose two.)

A. Install an additional 400 GB SSD and 4 x 1.8 TB SSDs per vSAN node.

B. Update the existing Disk Group, and claim the newly installed drives for each node.

C. Create a new Disk Group, and claim the newly installed cache and capacity SSD drives for each node.

D. Install an additional 3 x 1.8 TB SSDs per vSAN node.

E. Replace existing SSDs with an 800 GB SSD and 4 x 3.8 TB SSDs per vSAN node.

Correct Answer: CD


Question 15:

After a vSAN Witness Appliance network configuration, the vSAN administrator notices that vSAN traffic flows from vmk0 (Management Traffic) rather than vmk1 (vSAN Traffic).

Which step should be taken to resolve this issue?

A. Configure vmk0 with IP address on the same range as that of vmk1.

B. Tag the vmk0 for vSAN traffic.

C. Configure vmk1 with IP address on the different network than that of vmk0.

D. Tag the vmk1 for Witness traffic.

Correct Answer: A

If both vmk0 and vmk1 are configured on the same range, a multihoming condition will occur and vSAN traffic will flow from vmk0, rather than vmk1.

Reference: http://www.vmwarearena.com/vsan-stretched-cluster-how-to-configure-vsan-witnessappliance/


Leave a Reply

Your email address will not be published.